1. One damped oscillator links time, Laplace, and frequency descriptions
For a linear mass-spring-damper system excited by an external force $f(t)$, Newton’s second law gives a second-order constant-coefficient differential equation. Compare the impulse response $h(t)$, harmonic forced response, step response, and free release below while adjusting $m$, $k$, and $\zeta$.
Governing equation and transform triad
Linear limit: valid for constant mass, linear spring stiffness $k$, and linear viscous damping $c$. Nonlinear restoring forces introduce amplitude-dependent natural frequencies (backbone curves) and break superposition, so a single amplitude-independent FRF no longer describes the system.
2. The Fourier transform is the imaginary-axis slice of the Laplace transform
Write the complex frequency as $s = \sigma + \mathrm{i}\omega$. Because $\mathrm{e}^{-st} = \mathrm{e}^{-\sigma t}\mathrm{e}^{-\mathrm{i}\omega t}$, the unilateral Laplace transform is the Fourier transform of the exponentially weighted causal signal $x(t)\mathrm{e}^{-\sigma t}u(t)$. The real decay rate $\sigma$ provides a convergence factor that handles undamped or growing responses.
| Property | Laplace transform $\mathcal{L}\{x(t)\} = X(s)$ | Fourier transform $\mathcal{F}\{x(t)\} = X(\mathrm{i}\omega)$ |
|---|---|---|
| Domain & kernel | Complex $s$-plane ($s = \sigma + \mathrm{i}\omega$); damped sinusoids $\mathrm{e}^{-(\sigma+\mathrm{i}\omega)t}$ | Imaginary axis ($s = \mathrm{i}\omega$, $\sigma = 0$); pure persistent sinusoids $\mathrm{e}^{-\mathrm{i}\omega t}$ |
| Convergence | Converges in the right half-plane $\operatorname{Re}(s) > \sigma_0$ (ROC); handles undamped ($\zeta=0$) and unstable poles | Requires $\sigma = 0$ inside ROC (strictly stable $\zeta > 0$); undamped poles require generalized delta distributions |
| Initial conditions | Unilateral derivative rule $\mathcal{L}\{\ddot{x}\} = s^2 X(s) - s x(0^-) - \dot{x}(0^-)$ captures full transient + forced motion | Bilateral $(-\infty, \infty)$ rule $\mathcal{F}\{\ddot{x}\} = -\omega^2 X(\mathrm{i}\omega)$ assumes zero initial conditions or steady state |
| Role in vibrations | Poles, stability boundaries, decay rates ($-\zeta\omega_{\mathrm{n}}$), complete transient solutions, control design | Measurable steady-state FRFs, impact-hammer & shaker modal testing, PSDs, and spectral filtering |
3. Time-domain convolution equals multiplication in the transform domain
Any causal force history $f(t)$ is a superposition of delayed impulses, so the zero-initial-condition response is the Duhamel convolution integral of $f(t)$ with the impulse response $h(t)$. Transforming turns that integral into pointwise algebraic multiplication by the transfer function $H(s)$ or FRF $H(\mathrm{i}\omega)$.
4. Reading stiffness, damping, and mass regions from the FRF
Evaluating $H(s)$ along $s = \mathrm{i}\omega$ yields the complex receptance $\alpha(\mathrm{i}\omega) = \operatorname{Re}(\alpha) + \mathrm{i}\operatorname{Im}(\alpha) = |\alpha|\mathrm{e}^{\mathrm{i}\phi}$. Drag the copper frequency probe directly on the Bode plot to track the response across the stiffness-controlled ($\omega \ll \omega_{\mathrm{n}}$), damping-controlled ($\omega \approx \omega_{\mathrm{n}}$), and mass-controlled ($\omega \gg \omega_{\mathrm{n}}$) regimes.
5. Six frequency response functions: differentiation, reciprocals, and units
In the Fourier domain, time differentiation multiplies by $\mathrm{i}\omega$: velocity is $V(\mathrm{i}\omega) = \mathrm{i}\omega X(\mathrm{i}\omega)$ and acceleration is $\ddot{X}(\mathrm{i}\omega) = -\omega^2 X(\mathrm{i}\omega)$. Each factor of $\mathrm{i}\omega$ rotates the log-log magnitude slope by $+20\;\text{dB/dec}$, shifts phase by $+90^\circ$, and changes physical units. Inverting response-over-force ratios gives the three reciprocal impedance functions.
| FRF name (click to focus) | Definition | Exact 1-DOF expression | SI units | Low / high-$\omega$ slopes | Value at probe $\omega$ |
|---|
6. Step-by-step vibration workflow and reproducible code
Follow the five steps below to move cleanly between time, Laplace, and frequency descriptions, or copy the live MATLAB and Python scripts populated with your current system parameters.
Analytical & experimental checklist
-
1
Form the Laplace transfer function. Take the unilateral Laplace transform of $m\ddot{x} + c\dot{x} + kx = f(t)$ to separate the zero-state transfer function $H(s) = (ms^2 + cs + k)^{-1}$ from the initial-condition transient terms.
-
2
Inspect poles and the ROC. Compute $p_{1,2} = -\zeta\omega_{\mathrm{n}} \pm \mathrm{i}\omega_{\mathrm{d}}$. Confirm $\operatorname{Re}(p_{1,2}) < 0$ so the imaginary axis $s = \mathrm{i}\omega$ lies inside the ROC.
-
3
Restrict to $s = \mathrm{i}\omega$ for steady-state FRFs. Evaluate $\alpha(\mathrm{i}\omega) = H(\mathrm{i}\omega)$ to obtain Bode magnitude/phase, quadrature peaks, and steady-state harmonic response $X(\mathrm{i}\omega) = \alpha(\mathrm{i}\omega)F(\mathrm{i}\omega)$.
-
4
Match the FRF type to your sensor. Accelerometers yield $A(\mathrm{i}\omega)$, vibrometers yield $Y(\mathrm{i}\omega)$, and displacement probes yield $\alpha(\mathrm{i}\omega)$. Convert between them using factors of $\mathrm{i}\omega$ and track SI units explicitly.
-
5
Identify modal parameters. Read $\omega_{\mathrm{n}}$ from the $\operatorname{Re}(\alpha) = 0$ crossing or mobility peak, extract $\zeta$ from the $-3\;\text{dB}$ half-power bandwidth or mobility Nyquist circle diameter $1/c$, and verify asymptotes ($1/k$ and $1/m$).